Problems a user can hit, by symptom.

Building with HDF5

Reading and writing arrays needs the hdf5 feature, and therefore the HDF5 library.

Windows: Unable to infer HDF5 library runtime version

The build script of hdf5-metno-sys fails with this message, which looks like a PATH or HDF5_DIR problem.

  • Cause: the installed hdf5.dll is the Intel/Fortran variant, which imports libmmd.dll (an oneAPI runtime) that is not on the disk. The message never names the real cause. dumpbin /DEPENDENTS hdf5.dll shows libmmd.dll when it is the case.
  • Solution: use only the official MSVC build of HDF5 1.14.6 (hdf5-1.14.6-win-vs2022_cl.zip), installed outside Program Files, with HDF5_DIR pointing at it. Copy its hdf5.dll next to the executable (the executable’s folder wins over PATH).

Invalid H5_VERSION: 2.2.0

The version check of hdf5-metno-sys only accepts a fixed set of minor versions and does not know HDF5 2.x. Stay on HDF5 1.14.6. If a 2.x install is earlier on PATH, test binaries load it: this works in practice but is not the version they were compiled against.

h5dump / h5ls print nothing and exit 53

Some installed builds are unusable. Do not spend time on them: to check what an HDF5 file really holds from outside the library, read it with h5py.

Binaries without HDF5

Where HDF5 cannot be compiled, a binary can be built without it. It then refuses by name to read an array (FeatureNotEnabled) instead of returning an empty one. An empty result with no error is never the library’s way of saying “no HDF5”.

Python

ImportError: DLL load failed on Windows

import energyml.rust fails on a machine without HDF5, and putting HDF5 on PATH does not help (Python 3.8+ no longer searches PATH for the dependencies of an extension module).

  • Cause: a wheel built locally without bundling HDF5. maturin --auditwheel is a Linux flag; on Windows it does nothing and does not say so.

  • Solution: repair the wheel with delvewheel, naming the namespace package so that it does not write energyml/__init__.py over the other energyml.* distributions:

    delvewheel repair --namespace-pkg energyml --add-path "$HDF5_DIR/bin" -w wheels staging/*.whl
    

    Released wheels already carry HDF5.

Another energyml.* package disappeared after install

Two distributions that both ship energyml/__init__.py overwrite each other. This bridge ships none. If one is missing, reinstall the other.

Opening and checking packages

Arrays cannot be found after a rename or move

An EPC names its .h5 in every array pointer and in the .rels of parts that go through a proxy. If you renamed or moved the file by hand, the package opens and its arrays are unreachable.

  • Find where each array really is: energyml h5 model.epc; write the answer into the package with energyml h5 model.epc --fix fixed.epc.
  • Offer the file explicitly: energyml --h5 renamed.h5 ..., or --h5 model.h5=path/to/renamed.h5 to pin a path to the name the document uses.
  • To rename on purpose, use energyml rename model.epc --to new.h5 (quote), then --apply: fields, relationships and the file change together.

The order in which the files are tried, and what the command says when it goes somewhere the package did not point, is in Where the arrays are looked for.

rename fails on Windows with a file in use

An HDF5 handle still open on a file locks it. The rename operation releases the handles it holds first; close any other program that has the file open.

An object is read in the wrong release, or as a development drop

Check the declared versions: energyml list model.epc. A package written against a development drop but declaring the release reads as the release and silently drops what only the drop has. energyml relabel model.epc --package resqml --schema-version 2.2_dev3 corrects the declaration without reading the content.

A part is refused

energyml repair model.epc lists the parts no parser will touch (markup that does not close, invalid UTF-8, an empty part) with the reason. --extract writes their bytes out, --apply puts repaired bytes back. --lenient reads past an absent required element or an unreadable value and reports each; do not save what it read, because it holds values nobody wrote (use --strict when writing).

check reports a dangling reference to a PropertyKind

A well-known PropertyKind of the Energistics catalogue is absent from a package by design; such references are reported as catalogue references and count as neither error nor warning. Any other dangling reference is real.

A coordinate looks plausible and is wrong

Check the unit and the placement: energyml geometry model.epc --points --metres. A file whose horizontal unit is feet read as metres is 3.28 times too far from the origin with every number looking reasonable. A unit the library does not know is refused, not assumed.

GeoJSON objects are missing, or land in the wrong place

GeoJSON is always WGS 84, so energyml export --format geojson needs the EPSG code of each object’s CRS. An object whose CRS names none is skipped, never placed anywhere: the command prints N skipped: geojson cannot write them, adding that objects without a usable EPSG code are skipped. Check energyml geometry for the CRS the package states; an eml 2.3 CRS is three objects and the code lives in the third.

--native-crs writes those objects anyway, in their stored coordinates, with the legacy crs member naming the EPSG code when there is one. The file is then not WGS 84, and the command says so. Small local coordinates read as degrees sit near longitude 0, latitude 0: the Gulf of Guinea.

Exports

“evaluated but could not be written”

One representation that cannot be written does not stop the others. The line names the object and the reason, for example a travel-time CRS that needs a velocity model the package does not carry. This is the usual shape of a refusal: the geometry evaluated fine and the placement has no answer.

Docker

Files are written by uid 1000 inside the container. On a Linux host, set the ownership of the mounted folder accordingly; Docker Desktop maps it to your user. An EPC and its .h5 must both be inside the mounted folder.

Still stuck